Remote control¶
/stm.cgi?remote¶
-
Configure the remote control settings.
GET /stm.cgi?remote=A*B*C*D*E*F*G*H*I*J*K*L*M*N*O*P*Q
A
determines whether the function is enabled, integer0-1
B
determines which fields are selected for Active_low, integer0-4095
(12 bits sequentially for INPD1-INPD4, EVENT1-EVENT8)C
is the host of controlled LC, stringD
is a port for communication with another LC, integerE
is the password, stringF
determines which fields are selected for INPD1, integer0-1023
(8 bits sequentially for OUT0-OUT5, PWNM0-PWM3)G
determines which fields are selected for INPD2, integer0-1023
(8 bits sequentially for OUT0-OUT5, PWNM0-PWM3)H
determines which fields are selected for INPD3, integer0-1023
(8 bits sequentially for OUT0-OUT5, PWNM0-PWM3)I
determines which fields are selected for INPD4, integer0-1023
(8 bits sequentially for OUT0-OUT5, PWNM0-PWM3)J
determines which fields are selected for EVENT1, integer0-1023
(8 bits sequentially for OUT0-OUT5, PWNM0-PWM3)K
determines which fields are selected for EVENT2, integer0-1023
(8 bits sequentially for OUT0-OUT5, PWNM0-PWM3)L
determines which fields are selected for EVENT3, integer0-1023
(8 bits sequentially for OUT0-OUT5, PWNM0-PWM3)M
determines which fields are selected for EVENT4, integer0-1023
(8 bits sequentially for OUT0-OUT5, PWNM0-PWM3)N
determines which fields are selected for EVENT5, integer0-1023
(8 bits sequentially for OUT0-OUT5, PWNM0-PWM3)O
determines which fields are selected for EVENT6, integer0-1023
(8 bits sequentially for OUT0-OUT5, PWNM0-PWM3)P
determines which fields are selected for EVENT7, integer0-1023
(8 bits sequentially for OUT0-OUT5, PWNM0-PWM3)Q
determines which fields are selected for EVENT8, integer0-1023
(8 bits sequentially for OUT0-OUT5, PWNM0-PWM3)
Example:
http://192.168.1.100/stm.cgi?remote=0*15*ip.com*30000*password*0*0*0*0*0*0*0*0*0*0*0*0